| Sign In | Join Free | My brakesband.com |
|
Brand Name : GENY
Model Number : YC1891D-12
Certification : ISO, CE
Place of Origin : CHINA
MOQ : 1 PCS
Price : Negotiation
Payment Terms : L/C,T/T,D/P
Supply Ability : 100/Year
Delivery Time : 30 days after order confirmed
Packaging Details : Plywood Case
Accuracy : 0.05
Power Source : YCS-101-600
Standard Meter : SZ-01A-K3
MSTV : HJ200G-12
Scanning Head : YCG-2-series
YC1891D Meter Test Equipment is a high-precision, stable, and highly automated meter test system independently developed and manufactured by our company. Backed by years of experience in energy meter testing and calibration, the system is widely used by utilities, metering laboratories, and energy meter manufacturers. It features high testing accuracy, strong system stability, intelligent automation, and flexible configuration, effectively reducing manual intervention, improving testing efficiency, and lowering overall operating costs. The system fully supports mechanical meters, electronic mechanical meters, and electronic meters, and complies with international meter testing standards.
| Environment | Power Requirement | Safety | |||
| Operation | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
| Temperature | |||||
| -10°C--+40°C | 35%--85% | < 2500m | 3x220/380v±10%(or customized) | IP 30 | CE conformity |
| 50/60Hz±2Hz | |||||
| Voltage | |||||
| Test voltage output (Phase-Neutral) | 24V-300V(or customized) | ||||
| Power of the voltage output | Max.250VA | ||||
| Resolution | Better than 0.01% of full scale value of range | ||||
| Setting accuracy | Better than 0.05% at the final range value | ||||
| Stability | Better than 0.005%/h(integration time 150 s) | ||||
| Load regulation from O-max.load | Better than 0.01% | ||||
| Distortion factor | Better than 0.3% for linear resistance load | ||||
| Harmonics | 2nd - 41st free programmable | ||||
| Current | |||||
| Test current output | 1mA-120A/200A | ||||
| Power of the current output | Max.250VA Max.500VA Max.1000VA Max.2000VA | ||||
| Resolution | Better than 0.01% of full scale value of range | ||||
| Setting accuracy | Better than 0.05% at the final range value | ||||
| Stability | Better than 0.005%/h(integration time 150 s) | ||||
| Load regulation from O-max.load | Better than 0.01% | ||||
| Distortion factor | Better than 0.3% for linear resistance load | ||||
| Harmonics | 2nd - 41st free programmable | ||||
| Phase angle | |||||
| Phase angle | 0°-360° | ||||
| Resolution | 0.01° | ||||
| Setting accuracy | 0.1° | ||||

|
|
Single Phase Intelligent Meter Test Equipment for Energy Meter Calibration Images |